This category contains 9 automated control definitions and 1 manual check across the sources named below. Similar controls from different standards are listed separately because names, thresholds or severity can differ. Whether the seeded Alignr Baseline is available depends on how your workspace was provisioned. Library templates are copied as disabled drafts. See Choose a baseline before enabling anything.

Automated controls

Expand a control to see the exact population, expectation and defaults. A pass requires usable evidence for the selected population. A known contrary observation can prove failure; missing observations or an empty population must not become a pass.
Each selected device should report an installed EDR agent.Part of Alignr Baseline (seeded).Applies toDevices reported as managed by an RMM.What the result tells youAgent installation is not agent health or recent reporting. Correlate the same endpoint across sources.
Each selected device should have a check-in timestamp within the configured day window.Part of Alignr Baseline (seeded).Applies toDevices reported as managed by an RMM.Default settingsClient overrides can change these values. Check the effective settings when interpreting a result.What the result tells youThe time window includes timestamps before or after now. Investigate unexpected future timestamps.
Each selected device should report a compliant patch status.Part of Alignr Baseline (seeded).Applies toDevices reported as managed by an RMM.What the result tells youThe expected state is the exact string compliant. Review the source’s patch scope; this does not prove absence of every vulnerability.
Each selected device should report encryption enabled.Part of Alignr Baseline (seeded).Applies toDevices with an MDM enrolment observation.What the result tells youReported encryption does not establish recovery-key custody or successful recovery.
Each selected device should report a compliant MDM state.Part of Alignr Baseline (seeded).Applies toDevices with an MDM enrolment observation.What the result tells youCompliant means compliant with the MDM source’s configured policies, not every Alignr expectation.
Each selected device should have a check-in timestamp within the configured day window.Part of BIOS Endpoint and Server Health.Applies toDevices reported as managed by an RMM.Default settingsClient overrides can change these values. Check the effective settings when interpreting a result.What the result tells youThe time window includes timestamps before or after now. Investigate unexpected future timestamps.
Each selected device should report a compliant patch status.Part of BIOS Endpoint and Server Health.Applies toDevices reported as managed by an RMM.What the result tells youThe expected state is the exact string compliant. Review the source’s patch scope; this does not prove absence of every vulnerability.
Each selected device should report an installed EDR agent.Part of BIOS Endpoint and Server Health.Applies toDevices reported as managed by an RMM.What the result tells youAgent installation is not agent health or recent reporting. Correlate the same endpoint across sources.
Each selected device should report encryption enabled.Part of BIOS Endpoint and Server Health.Applies toDevices with an MDM enrolment observation.What the result tells youReported encryption does not establish recovery-key custody or successful recovery.

Manual checks

These are human reviews, not automated evidence. The interval below is the template default; review ownership, evidence and suitability for the client.
Review every 30 days · BIOS Endpoint and Server HealthReview local admin, service accounts, host firewall, secure protocols and approved exceptions using your approved runbook. Connector facts do not currently prove these settings.Record: who performed the review, when it was performed, the evidence, the conclusion and any follow-up or approved exception. A due review is not evidence of a completed review.

Investigate a result

Confirm the client and the account, device or other item being assessed. Check the source, observation time and effective settings, then compare the recorded evidence with the expectation. Missing evidence needs investigation; a change to the environment requires a separate review.

Next steps

Create a custom control · Parameters and client overrides · Record a manual check